Best Material Vacuum Casting PMMA

Composition ISOCYANATE PX 521HT A POLYOL   PX 522HT B MIXING
Mixing ratio by weight 100 55
Aspect liquid liquid liquid
Colour transparent bluish transparent*
Viscosity at 25°C                         (mPa.s) Brookfield LVT 200 1,100 500
Density of parts before mixingDensity of the cured product ISO 1675: 1985ISO 2781: 1996 1.07- 1.05- -1.06
Pot life at 25°C on 155g                   (min) - 5 - 7
*PX 522 is available in orange ( PX 522HT OE Part B) and in red (PX 522HT RD Part B) Vacuum Casting Processing Conditions • Use in a vacuum casting machine. • Heat the mould at 70°C (preferably polyaddition silicon mould). • Heat both parts at 20°C in case of storage at a lower temperature. • Weigh part A in the upper cup (do not forget to allow for residual cup waste). • Weigh part B in the lower cup (mixing cup). • After degasing for 10 minutes under vacuum pour part A in part B and mix for 1 minute 30 to 2 minutes. • Cast in the silicone mould, previously heated at 70°C. • Put in an oven at 70°C minimum. • Demould after 45 minutes at 70°C. • Carry out the following thermal treatment : 3 hr at 70°C + 2 hr at 80°C and 2hr at 100°C. • Always while curing, place the part on stand. Handling Precautions Normal health and safety precautions should be observed when handling these products : • ensure good ventilation • wear gloves and safety glasses For further information, please consult the product safety data sheet.
Flexural modulus ISO 178 : 2001 MPa 2.100
Flexural strength ISO 178 : 2001 MPa 105
Tensile modulus ISO 527 : 1993 MPa 2.700
Tensile strength ISO 527 : 1993 MPa 75
Elongation at break in tension ISO 527: 1993 % 9
Charpy impact strength ISO 179/1 eU : 1994 kJ/m2 27
Final hardness ISO 868 : 2003 Shore D1 87
Glass temperature transition (Tg) ISO 11359  : 2002 °C 110
Heat deflection temperature ( HDT 1.8 MPa) ISO 75 Ae :1993 °C 100
Maximal casting thickness mm 10
Demoulding time at 70°C (thickness 3 mm) min. 45
Shelf life of both parts is 12 months in a dry place and in their original unopened containers at a temperature between 15 and 25°C. Any open can must be tightly closed under dry nitrogen.